MLC 226 IP Series • Setup Guide
The Extron MLC 226 IP Series MediaLink
®
Controller integrates Ethernet connection into
AV systems to allow users to remotely control, monitor, and troubleshoot AV equipment, including display devices and
switchers. It includes an embedded web server, multiple serial ports, relays, and configurable digital I/O ports for use in
applications that require control and monitoring of multiple devices within an AV system.
The MLC 226 IP series of controllers are configured using the free Extron Global Configurator (GC) software. The MLCs
integrate seamlessly with Extron GlobalViewer
®
Enterprise (GVE) software and the free GlobalViewer web-based AV
resource management software for remote control applications. Global Configurator and other useful software applications
are available at www.extron.com.
A checklist of basic setup steps is provided at the end of this guide. For additional information see the help files and the
MLC 226 IP Series User Guide, available at www.extron.com.
Panels and Features
DISPLAY
MLC 226 IP
1
2
3
4
5
6
VOLUME
CONFIG
IR
ON
OFF
VCR DVD
LAPTOP PC
SCREEN
DOWN
AUTO
IMAGE
SCREEN
UP
AUX
VIDEO
DOC
CAM
PROJECTOR
RS-232/IR
NORMALLY OPEN
RS-232 12V
CM/ IR SCP
A B C D E
1 2
COMMON
COMMON
COMMON
GROUND
GROUND
GROUND
A
RELAYS
IR/SERIAL OUT
MLS PWR
3 4
B
5 6
C
S
A
S
B
AB
S
C
Tx/IR
Rx
GROUND
PWR SNS
GROUND
+12V OUT
Rx
Tx
GROUND
GROUND
+12V IN
+12V OUT
GROUND
CONT MOD
IR IN
SCP COM
HOST
CONTROL
R
1=DIGITAL I/O
2=Tx 3=Rx 5=GND
38400, N, 8, 1
PRESS TAB WITH
TWEEKER TO REMOVE
INTERCOM
AUDIO
OUT
LAN
LAN (IP)
Connector
Side View
Host Control
and
Digital I/O
Port
Bottom Panel
Rear Panel
Power
Input
(12 VDC)
IR/Serial
Output
Ports
Control
Module/IR/
SCP Ports
Projector
Control
Port
Relay
Ports
IP Intercom
Ports
Reset Button
and LED
(on side)
MLS
Switcher
Port
Front Panel
Display On and
Off Buttons
Volume Knob
and LEDs
IR Control
Receiver
IR Learning
Receiver
Config (RS-232
host control) Port
Input Selection
Buttons
Function or
Room
Control
Buttons
Cabling and Features
Attach cables using the following wiring diagrams as a guide. Full details are available in the MLC 226 IP Series User Guide.
CAUTION: Installation and service must be performed by authorized personnel only.
Control — Projector or Display
Bottom
Panel
PROJECTOR
RS-232/IR
C
M
/
IR
A B
C
Tx/IR
Rx
GROUND
PWR SNS
GROUND
+12V OUT
+12V OU
T
G
ROUND
CONT MO
D
Transmit (Tx)
Receive (Rx)
Ground ( )
IR transmit (Tx)
Ground ( )
Projector
or Display
IR Port
Receive (Rx)
Transmit (Tx)
Ground ( )
Bidirectional
Projector or
Display
RS-232 Port
+12VDC
Ground ( )
Power sense
Ground ( )
Digital input
Digital Input
oror
Sleeve ( )
Ring
(signal)
Tip (+12 V)
3.5 mm Stereo Plug
Extron
Power Sensor
(60-271-01)
On, high: >2.8 VDC
Off, low: <2.0 VDC
{
Infrared:
TTL level (0 to 5 V)
• Up to 1 MHz
Digital input:
• High: >2.8 VDC
• Low: <2.0 VDC
Select RS-232 protocol via
software or SIS command.
Signals are bidirectional, ±5 V.
RS-232 default protocol:
• 9600 baud
• 8 data bits • 1 stop bit
• no parity • no flow control
NOTE: Each projector or display may
require different wiring. See the
manual that came with the projector
or display, or the Extron device driver
communication sheet for details.
Projector RS-232 / IR / Digital Input Port(s)
Contents
MLC 226 IP Series • Setup Guide 1
Panels and Features 1
Cabling and Features 1
Control — Projector or Display 1
Control — Control Modules, SCP Control Panels (CM/IR/SCP Port) 2
Control — Relay 2
Control — IR/Serial Output 2
Control — MLS Switcher 3
Power 3
Control — LAN (Ethernet) 3
Control — Serial (Host Control, Cong) and Digital I/O 4
Communication — IP Intercom 4
About Global Congurator (GC) 4
What It Does 4
What To Set Up in GC 5
Conguration 5
Resources 5
Obtaining Control Drivers 5
Instructions, Information, and Assistance 5
Conguring for Network Communication 5
Network Conguration Options 5
Network Conguration Using ARP 5
Mounting 6
Setup Checklist: How to Proceed With Installation 6
Vue de la page 0
1 2 3 4 5 6

Résumé du contenu

Page 1 - Front Panel

1MLC 226 IP Series • Setup GuideThe Extron MLC 226 IP Series MediaLink® Controller integrates Ethernet connection into AV systems to allow users to re

Page 2 - Control — IR/Serial Output

2MLC 226 IP Series • Setup Guide (Continued)Control — Control Modules, SCP Control Panels (CM/IR/SCP Port)BottomPanelPROJECTORRS-232/IRCM/ IR/SCPA B

Page 3 - Control — LAN (Ethernet)

3Control — MLS Switcher12VRS-232GROUNDGROUNDGROUNDIR/SERIAL OUTMLS PWRAS BABS CRxTxGROUNDGROUND+12V IN12VGROUNDGROUNDGROUNDIR/SERIAL OUTPWRAS BLLS CGR

Page 4 - What It Does

4MLC 226 IP Series • Setup Guide (Continued)Control — Serial (Host Control, Cong) and Digital I/OCommunication — IP IntercomRINTERCOMAUDIOOUTAudio S

Page 5 - Resources

5By using GlobalViewer, users can manage, monitor, and control Extron and third-party equipment such as projectors, displays, computer monitors, Blu-r

Page 6

6MLC 226 IP Series • Setup Guide (Continued)Extron Headquarters+800.633.9876 Inside USA/Canada Only Extron USA - West Extron USA - East+1.714.491.15