Vue de la page 19
DVI DA Plus Series • Installation and Operation
Installation and Operation, cont’d
2-8
Power supply input
Connect the two pole, 3.5 mm captive screw connector from the
power supply (provided with the unit) to this orange socket on
the rear panel.
12V
1.0A MAX
POWER
Back Panel
Power Receptacle
DC Power Cord
Captive Screw Connector
AC Power Cord
Ground
+12 VDC
External
Power Supply
(12 VDC, 2 A )
The external power supply in the illustration above (12 VDC,
2A) is for use with the DVI DA4 Plus. The DVI DA6 Plus and
DVI DA8 Plus use a 12 VDC, 3A external power supply.